BLHYQ - CELITE STANDARD SUPER-CEL FILTER-CEL, 589
- MSDS: BLHYQ
- Manufacturer: MANVILLE SALES CORP
- Product Name: CELITE STANDARD SUPER-CEL FILTER-CEL, 589
- National Stock Number: 9390-00N020606
Product Identification
Product ID:CELITE STANDARD SUPER-CEL FILTER-CEL, 589
MSDS Date:11/15/1990
FSC:9390
NIIN:00N020606
MSDS Number: BLHYQ
Responsible Party
US
Emergency Phone: 303-978-4900
Info Phone: 303-978-4900
Cage: 75161
Contractor
Telephone: 303-978-2000
Cage: 75161
Ingredients
CALCINED DIATOMACEOUS EARTH
CAS: 91053-39-3
Fraction By Weight: 100%
OSHA PEL 5 MG/M3 RDUST (MFR)
ACGIH TLV: 10MG/M3 TDUST (MFR)
SILICA, CRYSTALLINE - CRISTOBALITE
CAS: 14464-46-1
RTECS: VV7325000
Fraction By Weight: <20%
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.05 MG/M3 RDUST9293
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
Fraction By Weight: <3%
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: TEMPORARY UPPER RESPIRATORY OR
EYE IRRITATION. CHRONIC: CRYSTALLINE SILICA HAS BEEN CLASSIFIED AS
PROBABLY CARCINOGENIC FOR HUMANS (2A) BY IARC. CRYSTALLINE SILICA
CAN CAUSE SILICOSIS, A NONCAN CEROUS LUNG DISEASE CAUSED BY
EXCESSIVEEXPOSURE TO CS.
Explanation of Carcinogenicity:CRYSTALLINE SILICA: GROUP 2A (IARC).
Effects of Overexposure:INHAL: IRRITATION OR SORENESS IN THROAT & NOSE.
IN EXTREME EXPOSURES SOME CONGESTION MAY OCCUR. SKIN
CONTACT/ABSORPTION: NOT APPLICABLE. INGEST: NOT HAZARDOUS WHEN
INGESTED. EYES: TEMPORARY IRRITATION OR REDNESS.
Medical Cond Aggravated by Exposure:PRE-EXISTING UPPER RESPIRATORY &
LUNG DISEASE SUCH AS, BUT NOT LIMITED TO BRONCHITIS, EMPHYSEMA, AND
ASTHMA.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT &
BLOW NOSE TO EVACUATE DUST. SKIN: NOT APPLICABLE. FLUSH W/COPIOUS
AMOUNTS OF WATER. CALL MD . INGEST: NOT APPLICABLE. CALL MD
IMMEDIATEL Y . EYES: FLUSH W/LARGE AMOUNTS OF WATER FOR A MINIMUM
OF 15 MINUTES. IF IRRITATION PERSISTS, CONSULT AN MD.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE REQUIRED. WEAR NIOSH/MSHA APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:VACUUM CLEAN W/EQUIPMENT FITTED WITH HEPA
FILTER. IF SWEEPING IS NECESSARY, USE A DUST SUPPRESSANT SUCH AS
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:REPAIR ALL BROKEN BAGS IMMEDIATELY.
INSURE PROPER RESPIRATORY PROTECTION WHEN REPAIRING/MAINTAINING OF
CONTAMINATED EQUIPMENT.
Other Precautions:THIS PROD CONTAINS CRYSTALLINE SILICA, A CHEM KNOWN
TO THE STATE OF CAL TO CAUSE CANCER. CS IS CONSIDERED A HAZ BY
INHAL. IARC HAS CLASSIFIED CS AS PROBABLY CARCIN FOR HUMANS (2A).
THIS CLASSIFICATION IS BASED ON THE FINDINGS (SUPP DATA)
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION
AS INDICATED: <10X PEL, HALF-MASK; <100X PEL FULL-FACE; <200X PEL
TYPE C SUPPLIED AIR (CONTINUOUS FLOW MODE).
Ventilation:USE SUFFICIENT NATURAL OR MECHANICAL VENTILATION TO KEEP
DUST LEVEL BELOW PEL.
Protective Gloves:NOT NORMALLY REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC: OF LAB ANIMAL STUDIES THAT WERE CONSIDERED SUFFICIENT &
DATA FROM EPIDEMIOLOGICAL (HUMAN) STUDIES THAT WERE CONSIDERED
LIMITED FOR CARCINOGENICITY. CS CAN CAUSE SILICOSIS, A NONCANCEROUS
L UNG DISEASE. FURTHER STUDIES ARE BEING CONDUCTED TO CLARIFY
POTENTIAL HLTH EFTS OF DIATOMACEOUS EARTH (DE).
Chemical Properties
HCC:N1
Spec Gravity:2.3
Solubility in Water:NEGLIGIBLE
Appearance and Odor:FINE PINK POWDER, NO ODOR.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID.
Stability Condition to Avoid:NONE IN DESIGNED USE.
Hazardous Decomposition Products:NONE DETERMINED.
Disposal
Waste Disposal Methods:WASTES ARE NOT HAZARDOUS AS DEFINED BY RCRA (40
CFR PART 261). COMPLY WITH FEDERAL, STATE, & LOCAL REGULATIONS.
METHOD OF DISPOSAL: LANDFILL; REPORTABLE QUANTITY: NOT APPLICABLE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.